ISO 17025 Accredited calibration
We are delighted to have received our Accreditation Certificate from DAkkS. We take care of your calibration.
Our all-round carefree service for LSProbe E‑Field Probes and LSPM RF Power Meters includes checking your measuring equipment and performing the accredited calibration.
Electric-Field Calibration and Measurement Capabilities (CMC)
Range
1 V/m – 20 V/m
3 V/M – 50 V/m
Measurement conditions
frequency: 9 kHz – 1 GHz
frequency: 1 GHz – 18 GHz
Remarks
TEM cell
anechoic chamber
Calibration procedure
Contact LUMILOOP to receive calibration quote/ RMA number
Send in LSProbe or LSPM for calibration service to Lumiloop
Inspection and test
After receiving the shipment, LUMILOOP analyses the calibration delivery:
– system inspection
– fiber connector cleaning (LSProbe)
– failure analysis
– failure report
– repair, if needed
ISO 17025 Accredited calibration
We perform the accredited calibration at LUMILOOP headquarters. If your requirements exceed our CMC, we coordinate your accredited calibration at one of our qualified partner labs.
Calibration data sanity checks
LUMILOOP checks the calibration data and converts the raw data to the format required by the LUMILOOP TCP Server.
Functional test
Functional test of complete set-up including all fiber optic cables.
Delivery to customer
You can order the following calibration services directly from us or your local sales partner:
LSProbe RE-Calibration* & Warranty Extension | Part No. |
---|---|
LSProbe 1.2 ISO 17025 Accredited RE-Calibration 9 kHz to 8.2 GHz | 1201 |
LSProbe 1.2 G ISO 17025 Accredited RE-Calibration 9 kHz to 8.2 GHz, 20/50 V/m | 1203 |
LSProbe 2.0 ISO 17025 Accredited RE-Calibration 9 kHz to 18 GHz | 1205 |
LSProbe 1.2 System Warranty Extension | 1221 |
LSProbe 2.0 System Warranty Extension | 1223 |
* When ordering a new LSProbe the initial ISO 17025 accredited calibration will be offered for a reduced price. |
LSPM Calibration Service | Part No. |
---|---|
LSPM 1.0/ LSPM 1.0+ ISO 17025 Accredited Calibration (9 kHz – 8.2 GHz) – Single-Channel | 2201 |
LSPM 1.0/ LSPM 1.0+ ISO 17025 Accredited Calibration (9 kHz – 8.2 GHz) – Dual-Channel | 2202 |
LSPM 1.0/ LSPM 1.0+ ISO 17025 Accredited Calibration (9 kHz – 8.2 GHz) – Triple-Channel | 2203 |
LSPM 1.1 ISO 17025 Accredited Calibration (9 kHz – 8.2 GHz) – Single-Channel | 2205 |
LSPM 1.1 ISO 17025 Accredited Calibration (9 kHz – 8.2 GHz) – Dual-Channel | 2206 |
LSPM 1.1 ISO 17025 Accredited Calibration (9 kHz – 8.2 GHz) – Triple-Channel | 2207 |
LSPM 2.0/ LSPM 2.0+ ISO 17025 Accredited Calibration (9 kHz – 26.5 GHz) – Single-Channel | 2211 |
LSPM 2.0/ LSPM 2.0+ ISO 17025 Accredited Calibration (9 kHz – 26.5 GHz) – Dual-Channel | 2212 |
LSPM 2.0/ LSPM 2.0+ ISO 17025 Accredited Calibration (9 kHz – 26.5 GHz) – Triple-Channel | 2213 |
LSPM 2.1 ISO 17025 Accredited Calibration (9 kHz – 26.5 GHz) – Single-Channel | 2214 |
LSPM 2.1 ISO 17025 Accredited Calibration (9 kHz – 26.5 GHz) – Dual-Channel | 2215 |
LSPM 2.1 ISO 17025 Accredited Calibration (9 kHz – 26.5 GHz) – Triple-Channel | 2216 |